TSI DUSTTRAK II Desktop 8530 Dust/Aerosol Monitor
TSI DUSTTRAK II Desktop 8530 Dust/Aerosol Monitor
TSI DUSTTRAK II Desktop 8530 Dust/Aerosol Monitor
TSI DUSTTRAK II Desktop 8530 Dust/Aerosol Monitor
TSI DUSTTRAK II Desktop 8530 Dust/Aerosol Monitor
TSI DUSTTRAK II Desktop 8530 Dust/Aerosol Monitor
TSI Instruments

TSI DUSTTRAK II Desktop 8530 Dust/Aerosol Monitor

Pine Item #51359

The new TSI 8530 DustTrak II Aerosol Monitor is a desktop battery-operated, data-logging, light-scattering laser photometer that gives you real-time aerosol mass readings. It uses a sheath air system that isolates the aerosol in the optics chamber to keep the optics clean for improved reliability and low maintenance. It is suitable for clean office settings as well as harsh industrial workplaces, construction and environmental sites, and other outdoor applications. The DustTrak II Aerosol Monitor measures aerosol contaminants such as dust, smoke, fumes, and mists.

Features:

Aerosol Concentration range 0.001 to 400 mg/m3

Automatic zeroing (with optional zero module) minimizes the effect of zero drift

Measure aerosol concentrations corresponding to PM1 PM2.5 PM10 or Respirable size fractions

Perform in-line gravimetric analysis for custom reference calibrations

Applications:

IAQ

Occupational Hygiene

Outdoor environmental monitoring

Baseline trending and screening

Engineering Control evalutations

Remote Monitoring

Process Monitoring

Emission Monitoring

Quantity must be 1 or more
Equipment available for both rental and purchase
Request a Quote

Specifications

Technical Specifications

Gravimetric Sampling8530/31 Removable 37 mm cartridge (user supplied)
Sensor type90° light scattering
Aerosol Concentration Range0.001 to 150 mg/m3
Resolution±0.1% of reading or 0.001 mg/m3 whichever is greater
Zero Stability±0.002 mg/m3 per 24 hours at 10 sec time constant
Flow Rate3.0 L/min set at factory 1.40 to 3.0 L/min user adjustable
Flow Accuracy±5% of factory set point internal flow controlled
Temperature Coefficient#ERROR!
Operational Temperature32 to 120°F (0 to 50°C)
Operational Humidity0 to 95% RH non-condensing
Data Logging5 MB of on-board memory (>60000 data points) 45 days at 1 minute logging interval
Log internalUser adjustable 1 second to 1 hour
Analog outUser selectable output 0 to 5 V or 4 to 20 mA User selectable scaling range
PowerSwitching AC power adapter with universal line cord included 115-240 VAC
CommunicationsUSB (host and device) and Ethernet. Stored data accessible using flash memory drive
Alarm outRelay or audible buzzer Relay Non-latching MOSFET switch User selectable set point -5% deadband Connector 4-pin Mini-DIN connectors
DimensionsUS: 5.3 x 8.5 x 8.8 in. Metric: 13.5 x 21.6 x 22.4 cm
WeightUS: 3.5 lb. Metric: 1.6 kg
Manuals & Data Sheets